-13% Cyrix-Li-Charge 24/48V-120A

Cyrix-Li-Charge

The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay: - if the Charge Disconnect output of the VE.Bus BMS is high, and - if it senses 13,7V (resp. 27,4V or 54,8V) or more on its battery charger connection terminal, and - if it senses 2V or more on its battery terminal (the Cyrix will remain open, if not connect to the battery). The Cyrix-Li-Charge will disengage immediately whenever its control output becomes free floating, signalling cell over voltage or cell over temperature. In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger. After 2 attempts to reengage with 3 seconds delay, the delay increases to 10 minutes. Whenever battery voltage is less than 13,5V (resp. 27V or 54V), the Cyrix will disengage with a delay of 1 hour. Note 1: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected, because battery voltage will remain higher than 13,5V. Note 2: If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,7V or more, the Cyrix will reengage, with 3 seconds delay

Write a review

Note: HTML is not translated!
    Bad           Good

For Help, Please contact the office on 0141 280 5454

Cyrix-Li-Charge 24/48V-120A

  • Views: 155
  • Product Code: Cyrix-Li-Charge 24/48V-120A
  • SKU: CYR020120430
  • Availability: In Stock
  • £80.40
  • £70.35
  • Ex Tax: £58.63
  • 1 or more £70.35